9694 - AC Clamp On Sensor, 5A, 40 Hz to 5 kHz
AC current probe, CAT III 300 V, measurement range up to 5 A AC, basic accuracy ±0.3% rdg., phase accuracy ±2°, frequency range 40 Hz to 5 kHz, max. conductor diameter 15 mm, operating temperature 0 °C to 50 °C
Available stock:
3
Product number:
9694
EAN:
4536036007448
Length:
135 mm
Width:
24 mm
Height:
46 mm
Weight:
0.23 kg
Product information 9694 - AC Clamp On Sensor, 5A, 40 Hz to 5 kHz
Key Specifications
- AC currents up to 5 A, continuous 50 A (45 to 66 Hz)
- Frequency Bandwidth 40 Hz to 5 kHz
- Basic accuracy: ±0,3% rdg.,
- Operating temperature: 0°C to 50°C
- Output voltage ratio 10 mV / A
Typical Applications
- AC current measurement on conductors rated for 5 A nominal current (continuous measurement up to 50 A)
- Current monitoring and logging in industrial AC power systems and branch circuits
- Measurement of output current and basic harmonic analysis in inverter-driven loads
- Installation in confined spaces, such as inside control cabinets or distribution boards
Detailed Product Overview
Basic amplitude accuracy is ±0.3% of reading, while phase accuracy is ±2° between 45 Hz and 5 kHz. In the extended frequency range from 40 Hz to 5 kHz, amplitude deviation is ±1%. The output signal of 10 mV/A is delivered via a fixed 3-meter cable with BNC connector, suitable for voltage-input instruments such as the Hioki PW3360 and PW3365.
- 9694 Clamp On Sensor
- Instruction Manual
-
Product brochure with data sheet, clamp on power logger PW3360 (English)4,790 KB pdf
-
Product brochure with data sheet, clamp on power logger PW3365 (English)8,286 KB pdf
-
Product catalog with data sheet, current sensors & current probes series (English)15,125 KB pdf
-
Product catalog with datasheet, Selection guide, Power Quality Analyzers / Power Loggers (English)3,584 KB pdf
-
Instruction Manual, Clamp on Sensor 9694 (Japanese, English)511 KB pdf